Heat pumps · practical guide

Heat pumps and dynamic electricity prices: when can heating shift?

Some homes can move part of a heat pump’s electricity use to different hours. Any shift must still respect heat demand, comfort and the system’s efficiency.

Shift operation within comfort limits

1Heat demandrooms and hot water
2Possible windowprice and system
3Comfort limitcontroller's safeguards
Schematic illustration. The temperature line is not a recommended setting or a measurement from a particular home.

What can shift, and what cannot?

A heat pump cannot always choose freely when a home gets heat. Weather, building heat loss, occupants’ needs and hot-water use set the boundaries. Some buildings can temporarily store a little extra heat in their structure or a tank; others have very little flexibility.

Shifting operation should mean placing some necessary heating within a suitable time window — not letting rooms become cold or exceeding the manufacturer’s limits. The heat pump’s own controls should continue to protect comfort and safe operation.

The electricity price is only part of the calculation

With a variable electricity contract, power can cost different amounts in different intervals. The relevant figure is the total variable price for electricity imported at that time, not the wholesale spot price alone.

Compare the price difference with any change in heat pump efficiency. If shifting requires higher water temperatures or less favourable operating conditions, the electricity saving may shrink or disappear. A cheap hour does not automatically mean cheaper delivered heat.

COP and outdoor conditions matter

COP describes the relationship between heat delivered and electricity used under specified conditions. Actual efficiency changes with the heat source, outdoor temperature and requested flow temperature. Seasonal ratings do not tell you exactly how a particular installation performs in every interval.

Use measurements from your own system if you want to check the economics: compare electricity, heat output and temperatures over similar periods. Do not claim more precision than the sensors provide.

Start with the heat pump's own controls

Keep weather compensation, heating demand and safety settings as the baseline. If an energy manager can influence operation, it should shift additional heat production only when the economic case is clear and the system has room to store the heat.

A tank or building can act as limited thermal storage, but stored heat is lost. If it dissipates before it is needed, earlier operation was not free. This matters when cheap electricity is far ahead of the actual heat demand.

Where Fluks fits

Fluks can compare available prices and measurements with devices that support control. For heating, that means looking for economically useful flexibility above normal operation while the heat pump’s own controller remains responsible for comfort and base heat.

The result depends on which temperatures, energy measurements and control functions the installation makes available. A system should reflect uncertainty when measurements or forecasts are not enough for a confident calculation.

Technical background

Energy Saving Trust: running a heat pump efficiently ↗